Custom-made flow cytometry analysis

Study Overview

Flow cytometry is an analytical method that uses a laser to detect fluorescent signals and other signals. It allows for simultaneous, high-speed analysis and quantification of various characteristics of individual cells in a large cell population. A variety of analyses are possible, including the examples below.

In addition to offering contract flow cytometry analysis services using samples provided by our clients, we also provide custom cell-based assay services. We can conduct integrated testing from various cell cultures, through test substance treatment, to flow cytometry analysis.

We also offer analysis services using a cell sorter, a type of flow cytometer that separates cells.

Please feel free to contact us.

Equipment used

CytoFLEX S (Beckman Coulter)

Features of the CytoFLEX S

  • Measure a 96-well plate in 32 minutes
  • Switch between single tube and plate formats in just 5 minutes
  • Supports analysis using a plate loader
  • Bead assay enables simultaneous measurement of various cytokines

Typical analysis examples

  • Cell cycle
  • Apoptosis
  • Cell surface antigens (e.g., CD markers)
  • Immune cell assessment (lymphocyte subset analysis)
  • Intracellular cytokine analysis
  • Multiplex quantification of multiple cytokines in culture supernatant and serum
  • Detection and quantification of various biomarkers
  • Analysis of stem cell differentiation status

CytoFLEX S Specifications

LaserFluorescence Channel
Violet 405 nm450/45 BP
525/40 BP
610/20 BP
660/20 BP
Blue 488 nm525/40 BP
690/50 BP
Yellow 561 nm585/42 BP
610/20 BP
690/50 BP
780/60 BP
Red 638 nm660/20 BP
712/25 BP
780/60 BP

*The wavelength can be changed by inserting a filter.

Main fluorescent dyes that can be analyzed
Pacific Blue dye, V450, eFluor450, BV421, Krome Orange, AmCyan, V500, BV510, BV605, Qdot 605, BV650, Qdot655, FITC, Alexa Fluor488, CFSE, Fluo-3, PC5.5, PC5, PerCP, PerCP-Cy5.5, PI, PE, DsRED, tdTomato, ECD, PE-Texas Red, PE-CF594, mCherry, PC7, APC, Alexa Fluor647, eFluor660, APC-A700, Alexa Fluor700, APC-A750, APC Cy7, APC-H7, APC eFluor750 など

References

Single-cell analysis of human ovarian cortex identifies distinct cell populations but no oogonial stem cells
Wagner et al., Nature Communications 2020

A Novel Semiconductor-Based Flow Cytometer with Enhanced Light-Scatter Sensitivity for the Analysis of Biological Nanoparticles
Brittain IV et al., Scientific Reports 2019


*Studies will be mainly conducted by those with doctoral degrees.